HotLoop Gateway: One Historian, One Write Gate, Every PLC on Site
A sensor fails at 3 a.m. The gateway reads the dead input as zero. Zero is below the low alarm. Somebody gets paged, drives in, and finds a full tank and a healthy process. The only broken thing is the instrument, and the system never said so.
The HotLoop Gateway is built around that failure. Its product page says it in six words: every reading is real, every write is earned.
What it does on the floor
The Gateway runs a whole site from one box. It connects to your PLCs, drives, and meters over the protocols they already speak, keeps every value with its quality, alarms to ISA-18.2, and rolls up every site onto one screen. Three ideas carry the product.
Bad is not zero. Every reading carries good, uncertain, or bad. A driver that cannot read a point still reports, marked bad, because silence looks exactly like a value that has not changed. Alarms hold their state on a bad reading instead of evaluating it, so a dead instrument shows up as a dead instrument and not as a process upset. The Gateway page has a live simulation where you pull the wire on a sensor and watch which system pages somebody for nothing.
One write gate. The screen, a rule, a script, and an AI agent all go through the same gate with the same checks in the same order. Everything ships locked. The caller needs permission to write. The master writes switch ships off. Agents get their own switch, which can narrow the master but never open a door it closed. Every tag is read-only until somebody arms it on purpose, one at a time, so importing 4,000 tags arms none of them. An out-of-range value is refused and never clamped, because quietly sending 250 to somebody who typed 500 means they never find out. The device has to be running. And the audit row is written before the value goes out, so a write that hangs still left evidence that it was attempted.
Built for agents. Over a hundred tools let an AI agent read the plant and, behind a switch, change its configuration, with the permission of whoever it signs in as and a required reason. It reads the plant in entities, the infeed pump rather than register 40001, and it can act only through the gate. You can ask it why line 3 is slow and let it read everything, knowing it can touch only what you armed.
Around that sits the plant itself. Twelve native drivers cover OPC UA, Modbus, MQTT and Sparkplug B, EtherNet/IP, S7comm, MTConnect, HTTP and REST, SNMP, BACnet/IP, UniFi, CODESYS, and OPC UA PubSub, and each one is listed with exactly what it was tested against. The historian uses TimescaleDB when it is there. Alarms follow ISA-18.2, including the one that cleared before anyone acknowledged it, so the 3 a.m. trip that fixed itself is still on the list when the morning shift walks in. Scheduled reports go out as CSV or HTML, only good readings count, and an empty period says no data, never zero. Point one Gateway at the others and a Sites screen asks each one the question it would answer itself. A site that does not answer shows as unreachable, never as zero alarms.
How it runs on EmberNet
On EmberNet, the Gateway is a card in the App Store, listed under SCADA and HMI and under Data and historian. The HotLoop Gateway listing describes the install:
- Pick a node and deploy. From EmberCORE, an Admin or Engineer chooses the node at your site, and EmberNet installs it. The Gateway deploys as a single instance per node, with its database in the same release, so there is nothing else to wire up.
- It runs on EmberRTOS, beside everything else. EmberRTOS is the immutable, container-native OS on every EmberNet edge node, and its Headless edition is built for gateways and telemetry. The Gateway shares the node with whatever else the plant runs from the store, such as a CODESYS runtime or a broker.
- Open it in the console. The Gateway has a web interface, so it opens inside EmberCORE and can pop out into its own tab. The HotLoop Gateway install docs note that under EmberCORE the console finds it by itself and proxies it at the in-cluster address, with no ingress needed.
- Reach a remote site with no open ports. An app at a remote site is reached over Flux, which travels over outbound HTTPS on port 443. The site dials out, so there is no inbound rule, no port forward, and no public address on your PLC network. The Gateway opens exactly like a local app.
- Size it and back up the key. Size the node for the historian you plan to keep. Device passwords are encrypted at rest with a key made for your install and kept across upgrades, so keep a copy of it apart from your backups. Read HotLoop's upgrade guide before moving from an older release.
The Gateway also has friends in the same store. Edge Relays publish Sparkplug B to a broker, and the Gateway picks them up. Its fleet management can restart a relay or send it a new device file over the connection the relay dialed out on. HotLoop Edge serves the machine layer, and HotLoop IoT covers the small boxes. Fleet management is API-only for now, with no screen yet, and the product page says so.
Why this fits a plant that runs on EmberNet
EmberNet already gives you the hard parts around the Gateway: the OS that cannot drift, the console that opens the app, and the network that needs no inbound ports. The Gateway adds the part that is about your process: honest readings, honest alarms, and a write path nobody can talk their way around. If you are planning how all that data should be organized, my Unified Namespace white paper covers Sparkplug and ISA-95, and AI Belongs on the Line covers the rule I hold agents to: AI advises, the PLC decides.
What it costs
Every HotLoop product is under the HotLoop Source License Agreement 1.0. Home and lab use is free, there are no license keys, and nothing unlocks at runtime. Businesses run HotLoop through EmberNet, HotLoop's Gold Licensee, where business use has no direct cost, and the way in is a free Pilot. The HotLoop docs have a page on using HotLoop in a business. For a turnkey rollout with SLAs and a warranty, Fireball Industries is HotLoop's gold implementation partner, and you can start that conversation here.
Try to break the gate
Before you read another word, open the Gateway page and try to move a machine through the simulation. Everything ships locked, so your first try bounces. Unlock it one switch at a time and watch where it stops. Then read the Gateway docs and deploy one from the App Store.